Database: K12 EOP (request logging & monitoring)
The mental model
EOP workflows need to be:
- auditable (what input produced what output)
- observable (what step is it on, did it fail)
- recoverable (you can retry or inspect partial state)
To make that possible, K12 uses a small set of tables in the K12SAFETY schema.
The lifecycle (where each table is written)
Given a RequestID (string) and optionally a SessionID:
- Request accepted / logged →
K12SAFETY.log_EOP_TaskRequests - Monitoring/timeline updated →
K12SAFETY.log_EOP_TaskStatus - Async runner state tracked (when applicable) →
K12SAFETY.log_Jobs - Prompt override audited (when applicable) →
K12SAFETY.log_EOP_TaskRequestSystemPrompts - Final response persisted → back into
log_EOP_TaskRequests(+log_Jobs.result_payloadif async)
This separation is intentional: it allows querying “what was the request” independently from “what is the latest status”.
Tables (what they mean, how to query them)
K12SAFETY.log_EOP_TaskRequests (request + response envelope)
Purpose: the canonical row for “what request came in and what response did we produce”.
Primary lookup columns:
RequestID,SessionID,TaskName
Commonly used fields:
- Request side:
RequestFormName,RequestFormFieldContent,RequestPrompt,RawRequestJson - Response side:
ResponseStatus,ResponseMessage,ResponseIsEdit,ResponsePayloadJson,RawResponseJson - Correlation:
WorkflowRunId,EmergencyOperationPlanId,EmergencyOperationPlanConfigurationId
DDL: db/sqlproj/Mastra.Platform.K12SafetyDb/model/Tables/K12SAFETY.log_EOP_TaskRequests.sql
K12SAFETY.log_EOP_TaskStatus (status timeline)
Purpose: a time-ordered timeline of status updates for monitoring.
Why a separate table?
- You can record multiple transitions (
accepted→processing→success/failed) without rewriting the request row.
Key columns:
RequestID,SessionID,WorkflowRunId,Status,Message, timestamps
DDL: db/sqlproj/Mastra.Platform.K12SafetyDb/model/Tables/K12SAFETY.log_EOP_TaskStatus.sql
K12SAFETY.log_Jobs (async execution state)
Purpose: job-runner state for background execution.
Key columns:
request_id(PK),job_type,status,attempt_count,input_payload,result_payload,error
Important join detail:
log_Jobs.request_idisNVARCHAR(64).log_EOP_TaskRequests.RequestIDisNVARCHAR(200).- The system treats these as the same conceptual
requestId, but sizes differ.
DDL: db/sqlproj/Mastra.Platform.K12SafetyDb/model/Tables/K12SAFETY.log_Jobs.sql
K12SAFETY.log_EOP_TaskRequestSystemPrompts (prompt override auditing)
Purpose: persist the exact system prompt used for a request when an override is applied, so behavior can be reproduced.
Key columns:
(RequestID, SessionID)(unique),PlanId,SystemPromptOverrideUsed,PromptHash,MetaJson
DDL: db/sqlproj/Mastra.Platform.K12SafetyDb/model/Tables/K12SAFETY.log_EOP_TaskRequestSystemPrompts.sql
Debug playbook (copy/paste)
1) Find the request row
SELECT TOP (1)
ID, TaskName, RequestID, SessionID, WorkflowRunId,
ResponseStatus, ResponseMessage,
CreatedAt, ModifiedAt
FROM K12SAFETY.log_EOP_TaskRequests
WHERE RequestID = '...'
ORDER BY CreatedAt DESC;
2) See the status timeline
SELECT TOP (50)
ID, Status, Message, WorkflowRunId, CreatedAt, ModifiedAt
FROM K12SAFETY.log_EOP_TaskStatus
WHERE RequestID = '...'
ORDER BY CreatedAt ASC;
3) If async, inspect the job row
SELECT
request_id, job_type, status, attempt_count,
created_at, updated_at,
error
FROM K12SAFETY.log_Jobs
WHERE request_id = '...';
4) If behavior looks “prompt-dependent”, check prompt audit
SELECT TOP (1)
RequestID, SessionID, PromptHash, CreatedAt, ModifiedAt
FROM K12SAFETY.log_EOP_TaskRequestSystemPrompts
WHERE RequestID = '...';
Common failure modes
- Request exists but no status updates: the kickoff log succeeded but the workflow runner didn’t progress.
- Status shows success but response payload missing: check whether the payload landed in
log_Jobs.result_payload(async) vslog_EOP_TaskRequests.ResponsePayloadJson. - Hard-to-reproduce output: verify whether a prompt override was used (
log_EOP_TaskRequestSystemPrompts).
See also